Scroll to top

Polypropylene Vertical Laminar Clean Bench


In stock

Polypropylene Vertical Laminar Clean Bench

TopAir provides high-quality, safe Vertical Laminar Clean Benches. TopAir’s clean benches suck air from the room or hall space, transfer the air through a HEPA filter using a fan, and then clean the bench area with filtered air.

In Vertical Benches, the filtered air is channeled downwards through a filter installed at the top of the bench.

All components are produced by leading global companies, such as EBM Germany and AAF USA.

Clean benches are designed to supply a clean controlled work environment meeting Class 100/ISO5 cleanliness standard, resembling a clean room, with the additional advantages of portability and small dimensions.

Clean benches provide a high quality alternative to a clean room at a much lower cost and without massive construction.

The Clean Bench complies with production/test standard USA Federal Standard 209E / ISO 1- 144641 and can be customized to customer requirements.

Category:

Description

  • Vertical air stream producing clean air at ISO-5/ CLASS100 or ISO4/Class10 standards
  • Polypropylene structure assures stability, preventing bench movements throughout sensitive operations.
  • Compliance with production/test standard: USA Federal Standard 209E / ISO 1- 144641
  • User-friendly digital control system manages fan speed and lighting system operation; optional alert for filter blockage.
  • Work surface made of 304 stainless steel which does not emit particles
  • Side windows made of tempered glass, allowing an optimal view of work inside the unit
  • High quality, quiet fan from EBM Germany; the fan enclosure is padded with noise-absorbing material
  • Noise level < 58 DBA
  • Universal electrical outlet
  • Variety of sizes and materials
  • Eco-friendly, cost-effective LED lighting
Spec/Model HC-V90P HC-V120P HC-V150P HC-V180P
Outer Dimensions
W x D x H
1030 x 760 x 1250 mm

40.5 x 30 x 49.2″

1330 x 760 x 1250 mm

52.3 x 30 x 49.2″

1630 x 760 x 1250 mm

64.1 x 30 x 49.2″

1930 x 760 x 1250 mm

76 x 30 x 49.2″

Workspace
(W x D x H)
900 x 660 x 750 mm

35.4 x 26 x 29.5″

1200 x 660 x 750 mm

47.2 x 26 x 29.5″

1500 x 660 x 750 mm

59 x 26 x 29.5″

1800 x 660 x 750 mm

70.8 x 26 x 29.5″

Production /
Test Standard
USA Federal Standard 209E / ISO-14644-1, CE USA Federal Standard 209E / ISO-14644-1, CE USA Federal Standard 209E / ISO-14644-1, CE USA Federal Standard 209E / ISO-14644-1, CE
Air Velocity m/s 0.5 m/s, 100 FPM 0.5 m/s, 100 FPM 0.5 m/s, 100 FPM 0.5 m/s, 100 FPM
Cleanliness
within Workstation
Class-100 (FS 209E) ISO 5, ISO-14644-1 Class-100 (FS 209E) ISO 5, ISO-14644-1 Class-100 (FS 209E) ISO 5, ISO-14644-1 Class-100 (FS 209E) ISO 5, ISO-14644-1
Cabinet Material Polypropylene Polypropylene Polypropylene Polypropylene
Work Table
Material
Stainless steel SUS 304 Stainless steel SUS 304 Stainless steel SUS 304 Stainless steel SUS 304
Noise <58dB <58dB <60dB <62dB
Test Location Tested 20 cm from the work table, 1.2m above ground Tested 20 cm from the work table, 1.2m above ground Tested 20 cm from the work table, 1.2m above ground Tested 20 cm from the work table, 1.2m above ground
Power Supply
Options
110 / 220V, 50/60 Hz, Single phase 110 / 220V 50/60 Hz, Single phase 110 / 220V 50/60 Hz, Single phase 110 / 220V 50/60 Hz, Single phase
Illumination 800 LUX 800 LUX 800 LUX 800 LUX
Filter HEPA Filter Efficiency of 99,9995% at 0.3 Microns H14 (Optional ULPA filter) HEPA Filter Efficiency of 99,9995% at 0.3 Microns H14 (Optional ULPA filter) HEPA Filter Efficiency of 99,9995% at 0.3 Microns H14 (Optional ULPA filter) HEPA Filter Efficiency of 99,9995% at 0.3 Microns H14 (Optional ULPA filter)
Spec/Model HC-V90 HC-V120 HC-V160 HC-V180
Stand <br> WxDxH HC-V90-ST HC-V120-ST HC-V160-ST HC-V180-ST
UV Light HC-V90-UV HC-V120-UV HC-V160-UV HC-V180-UV
Separate <br> Table HC- V90-VB HC-V120-VB HC-V160-VB HC-V180-VB

Reviews (0)

There are no reviews yet.

Be the first to review “Polypropylene Vertical Laminar Clean Bench”

Your email address will not be published. Required fields are marked *