Scroll to top

Selectra Pro XS


In stock

Selectra Pro XS

More than other entry-level systems in a cost effective package. Typical throughput is 75 tests per hour.

Description

Processing Center
Sampling probe with integrated mixer and level sensing
The unique sampling probe streamlines sample and reagent level sensing, aspiration and mixing. That reduces complexity, enhances uptime and provides collision protection.

Combined sample and reagent rotor with cooling dome
The rotor ensures optimum temperature and humidity are maintained providing reagent on-board stability and integrity.
• 30 on-board reagent positions (inner ring with 15 cooled reagent positions).
• 25 sample, control and calibrator positions.

Disposable cuvettes
Reduced maintenance and water consumption while improving test turnaround time.

Bar code reader: test requisition, sample and reagent identification
Optional reagent and sample patient bar code further simplifies operations and eliminates potential errors.

Operator Interface
Easy to use
The simplicity of the software allows a skilled technician to operate the Selectra ProXS within an hour. Interactive and intuitive routines lead the operator to the results quickly. The system maintenance instructions are integrated in the software.

On-board Quality Control
QC results are stored in memory and are easily displayed on the screen. The software calculates the mean, standard deviation and coefficient of variation. Validation using Westgard rules and a display of the Levey Jenning plot are also included.

Three reagent system
The software supports a ‘three reagent system’. This feature makes the Selectra ProXS the ideal platform for special applications or sample pretreatment steps.

Throughout

  • Up to 75 tests per hour.

Reagent and Sample System

  • Inner rotor ring:
    15 reagent positions for 10 ml, 25 ml and 50 ml reagent bottles
    Optionally cooled to 10°C +/ 4°C at normal laboratory conditions.
  • Outer rotor ring:
    25 positions for (STAT) samples, controls and calibrators
    15 positions for reagent bottles
  • All positions fit 13×75 mm primary and secondary tubes and pediatric cups
  • All positions can be used for calibrators, controls, normal, pediatric and STAT samples.

Pipetting System

  • 100 μl reagent syringe:
    – R1 volume 110-400 μl
    – R2 volume 0-180 μl
    -R3 volume 0-180 μl
    – Programmable in 1 μl steps
  • 100 μl sample syringe:
    – Sample volume 1-30 μl
    – Programmable in 0.1 μl steps
    – Programmable dilution ratios 1:5 up to 1:100 in one step increments with 3 possible diluents
  • Pre-heated probe with level detection, collision protection and integrated mixer.

Cuvette Rotor

  • Disposable cuvette rotor with 48 cuvettes
  • Minimum measurement volume 220 μl
  • Measurement temperature 37°C, controlled by Peltier elements.

Light Source

  • Quartz-iodine lamp 12V-20W.
  • Wavelength Range
  • Optical unit with 8 position filter wheel
  • Automatic wavelength selection
  • 340, 405, 505, 546, 578, 620, 660 nm standard installed
  • One free position
  • Other wavelenghts available on request.

Photometric Range

  • -0.1 to 3.0 Absorbance
    Resolution 0.001 Abs.

Analytical Modes (Single, Dual and Triple reagent system)

  • Kinetic measurement with linearity check
  • Mono and bichromatic end point measurement with or without bichromatic reagent blank and/or sample blank correction
  • Two point measurement; with or without slope blank
  • Graphic plot of all measuring points
  • Automatic rerun with sample reduction
  • Non-linear calibration curves
  • Prozone check for immunology tests
  • Cut-off declaration
  • Calculated tests.

Quality Control

  • Up to 15 different controls can be defined, 3 per test
  • Westgard rules
  • Levey-Jennings plots
  • Quality control statistics.

Water Consumption

  • ~250 mL per hour.

Standards and Regulations

  • CE -IVD
  • CB.

Dimensions

  • 89 x 58 x 60 cm (W x H x D)
  • No peripherals
  • Weight: 67 kg.

Interface

  • State of the art Host-Query interface available
  • Host: RS 232 or Ethernet (TCP/IP) through LIS-2A protocol.

Environmental Conditions

  • Temperature: 15 – 32 °C
  • Humidity: 15 – 85% RH
  • Altitude: up to 2,000 m
  • Plumbing: No dedicated water or drain required
  • Electrical:
    – Voltage: 100 – 240 Vac
    – Frequency: 50 – 60 Hz
    – Power (max): 350 VA .

Options
Bar Code Reader

  • Hand held CCD bar code reader used for test requisition, reagent identification and automated programing of assays, controls, and calibrators.

Printer

  • Printer supported by MS Windows™

ProActive Maintenance Kit

  • Complete parts kit for annual preventive maintenance.

The enhanced test menu provides flexibility in reagent containers and increased on-board stability. New features enable automated programming of assays, with bar coded reagents, calibrators and controls streamlining operations and reducing errors. Optimum sized packaging further enhances efficiency.

  • Dedicated line of ready to use, liquid-stable assays, packaged to fit the BenchTop laboratory
  • Tied to proven methodologies, referenced and traceable to industry standards
  • Standardized results across ELITech Clinical Systems Selectra Family
  • Ongoing commitment to develop new methods and enhancements

Substrates

  • Albumin
  • Bilirubin, Direct
  • Bilirubin, Total
  • Blood Urea Nitrogen (BUN)
  • Cholesterol
  • Cholesterol, HDL
  • Cholesterol, LDL
  • Creatinine
  • Glucose
  • Microprotein
  • Total Protein
  • Triglycerides
  • Uric Acid

Enzymes

  • Alanine Aminotransferase (ALT/GPT)
  • Alkaline Phosphatase (ALKP)
  • Amylase
  • Aspartate Aminotransferase (AST/GOT)
  • Creatine Kinase MB (CK-MB)
  • Creatine Kinase NAC (CK-NAC)
  • y-glutamyl transpeptidase Plus (GGT Plus)
  • Lactate Dehydrogenas (LDH)

Electrolytes

  • Calcium
  • Iron
  • Magnesium
  • Phosphorus
  • Total iron binding capacity (TIBC)

Specific Proteins

  • α 1-acid glycoprotein (AGP or AAG)
  • Apo A1
  • Apo B
  • C-reactive Protein (CRP)
  • Haptoglobin
  • Hemoglobin A1c (HbA1c)
  • IgA
  • IgG
  • IgM
  • Microalbumin
  • Prealbumin
  • Transferrin

Reviews (0)

There are no reviews yet.

Be the first to review “Selectra Pro XS”