ELITex Staph


In stock

ELITex Staph

Latex slide agglutination test for the rapid identification of Staphylococcus aureus.

Description

Intended use

Staphylococci are a serious problem for hospital epidemiology. Among them, Staphylococcus aureus is the main pathogenic species and is responsible for septicemia and nosocomial infections.
Multi-drug resistance poses considerable therapeutic problems, particularly with respect to methicillin resistant staphylococci. The ability to rapidly differentiate Staphylococcus aureus from other staphylococci species is therefore a necessity in microbiological diagnosis.

The ELITex Staph is a slide agglutination test for the rapid identification of Staphylococcus aureus (MRSA included) from primary culture plates. It is rapid, easy-to-use and easy-to-read with results available within 1 minute.

Principle

Red latex particles are sensitized with three proteins:

  • Fibrinogen that reacts with “Clumping Factor”
  • The Fc fragment of human IgG that reacts with Staphylococcus aureus protein A
  • Anti-Staphylococcus aureus capsular polysaccharides polyclonal IgG.

The presence of Staphylococcus aureus is revealed by a strong agglutination reaction. In the absence of Staphylococcus aureus, no agglutination appears.

The test procedure is easy with results available in less than a minute.

The kit is complete and includes:

  • TEST LATEX
  • CONTROL LATEX (internal control)
  • Test cards
  • Single use sticks

Simple protocol

Easy-to-read and easy-to-interpret results

TEST LATEX CONTROL LATEX INTERPRETATION
NEGATIVE REACTION
The strain tested is not Staphylococcus aureus 
+
+ POSITIVE REACTION
The strain tested is Staphylococcus aureus
+ + UNINTERPRETABLE REACTION

Reagents and material

  • TEST LATEX:
    • Dispenser vial of 1.8 mL of sensitized latex
    • Ref. 22711 Quantity: 1
    • Dispenser vial of 2.4 mL of sensitized latex
    • ref. 22712 Quantity: 2
  • CONTROL LATEX:
    • Dispenser vial of 1.8 mL of unsensitized latex
    • Ref. 22711 Quantity: 1
    • Dispenser vial of 2.4 mL of unsensitized latex
    • Ref. 22712 Quantity: 2
  • TEST CARD:
    • Disposable reaction card
    • Ref. 22711 Quantity: 15
    • Ref. 22712 Quantity: 40
  • STICK:
    • Disposable mixing sticks
    • Ref. 22711 Quantity: 120
    • Ref. 22712 Quantity: 320

Stability and storage

  • The reagents are ready-to-use.
  • All the reagents are stored at 2-8°C. Do not freeze.
  • The results of the stability study indicate that the product has a tability of 18 months at 2-8°C from its manufacture.

Performance

  • ELITex Staph assay has a good sensitivity for methicillin resistant strains of Staphylococcus aureus (MRSA), producing little protein A and/or fibrinogen affinity factor. The sensitivity of the assay is 99.02% and its specificity is 99.07%.

Material required but not supplied

  • Incubator calibrated at 37°C
  • Contaminated waste container